Volume 39 Issue 5
May  2017
Turn off MathJax
Article Contents
FU Chuan. Design method for torsional tuned liquid column damper for eccentric frame structure[J]. Chinese Journal of Engineering, 2017, 39(5): 802-809. doi: 10.13374/j.issn2095-9389.2017.05.020
Citation: FU Chuan. Design method for torsional tuned liquid column damper for eccentric frame structure[J]. Chinese Journal of Engineering, 2017, 39(5): 802-809. doi: 10.13374/j.issn2095-9389.2017.05.020

Design method for torsional tuned liquid column damper for eccentric frame structure

doi: 10.13374/j.issn2095-9389.2017.05.020
  • Received Date: 2016-07-22
  • The torsional tuned liquid column damper (TTLCD) is a cost-effective passive device for reducing the torsional response of a plan-asymmetric building under wind or seismic load. In this paper, the equations of relative liquid motion in three kinds of TTLCDs, as well as the control forces with the reference point and various inclined angles of the upright columns were derived. The optimal TTLCD control parameters were given through transforming method of the TTLCD-structure equivalent to a TTMD-structure system using Den Hartog or Ikeda formulas. Finally, the TTLCD design method was evaluated and the TTLCD design process was described. The numerical results of a four-storey plan-asymmetric structure show that TTLCDs can effectively mitigate earthquake-induced coupled flexural torsional responses and that the proposed method is feasible.

     

  • loading
  • [3]
    Hochrainer M J, Adam C, Ziegler F. Application of tuned liquid column dampers for passive structural control//Proceedings of 7th International Congress on Sound and Vibration (ICSV7). Germany, 2000:3107
    [8]
    Fu C, Ziegler F. Vibration prone multi-purpose buildings and towers effectively damped by tuned liquid column-gas dampers. AJCE (Asian J Civ Eng), 2009, 10(1):21
    [9]
    Fu C. Application of torsional tuned liquid column gas damper for plan-asymmetric buildings. Struct Control Health Monit, 2011, 18(5):492
    [10]
    Ziegler F. Mechanics of Solids and Fluids. 2nd Ed. New York:Springer Science&Business Media, 1995
    [11]
    Fu C.Effective Damping of Vibrations of Plan-Asymmetric Buildings[Dissertation]. Vienna:Vienna University of Technology, 2008
    [12]
    Den Hartog J P. Mechanical Vibrations. 4th Ed. New York:McGraw-Hill, 1956
    [13]
    Ikeda T. Fundamentals of Piezoelectricity. New York:Oxford University Press, 1990
  • 加載中

Catalog

    通訊作者: 陳斌, bchen63@163.com
    • 1. 

      沈陽化工大學材料科學與工程學院 沈陽 110142

    1. 本站搜索
    2. 百度學術搜索
    3. 萬方數據庫搜索
    4. CNKI搜索
    Article views (687) PDF downloads(16) Cited by()