<listing id="l9bhj"><var id="l9bhj"></var></listing>
<var id="l9bhj"><strike id="l9bhj"></strike></var>
<menuitem id="l9bhj"></menuitem>
<cite id="l9bhj"><strike id="l9bhj"></strike></cite>
<cite id="l9bhj"><strike id="l9bhj"></strike></cite>
<var id="l9bhj"></var><cite id="l9bhj"><video id="l9bhj"></video></cite>
<menuitem id="l9bhj"></menuitem>
<cite id="l9bhj"><strike id="l9bhj"><listing id="l9bhj"></listing></strike></cite><cite id="l9bhj"><span id="l9bhj"><menuitem id="l9bhj"></menuitem></span></cite>
<var id="l9bhj"></var>
<var id="l9bhj"></var>
<var id="l9bhj"></var>
<var id="l9bhj"><strike id="l9bhj"></strike></var>
<ins id="l9bhj"><span id="l9bhj"></span></ins>
Volume 36 Issue 11
Jul.  2021
Turn off MathJax
Article Contents
FENG Jun-xiao, JIANG Min, ZHOU Wen-hua, WU Qi-ming, XIANG Shun-hua. Flow heat transfer and NOx emission characteristic of W-shaped radiant tubes with flue gas circulation[J]. Chinese Journal of Engineering, 2014, 36(11): 1552-1559. doi: 10.13374/j.issn1001-053x.2014.11.019
Citation: FENG Jun-xiao, JIANG Min, ZHOU Wen-hua, WU Qi-ming, XIANG Shun-hua. Flow heat transfer and NOx emission characteristic of W-shaped radiant tubes with flue gas circulation[J]. Chinese Journal of Engineering, 2014, 36(11): 1552-1559. doi: 10.13374/j.issn1001-053x.2014.11.019

Flow heat transfer and NOx emission characteristic of W-shaped radiant tubes with flue gas circulation

doi: 10.13374/j.issn1001-053x.2014.11.019
  • Received Date: 2014-06-10
    Available Online: 2021-07-19
  • In order to solve the large wall temperature difference and high NOx emission of W-shaped radiant tubes, this article introduces a kind of W-shaped radiant tube with flue gas circulation. A mathematical model of the radiant tube is established and the radiant tube is studied by the method of numerical calculation. On the basis of the model's reliability, the velocity field, temperature field and NOx emission are compared between the radiant tube and a conventional W-shaped radiant tube. The average gas velocity of the new radiant tube is three times that of the conventional radiant tube, and 57.6% flue gas is involved in recombustion in the new radiant tube. The maximum combustion temperature of the new radiant tube is 2260 K, which is 192 K lower than that of the conventional radiant tube. The wall temperature difference of the new radiant tube is 166 K,which is 76 K lower than that of the conventional radiant tube. The NOx emission of the new radiant tube is 9.9×10-5, but the NOx emission of the conventional radiant tube is 7.98×10-4, nearly seven times higher.

     

  • loading
  • 加載中

Catalog

    通訊作者: 陳斌, bchen63@163.com
    • 1. 

      沈陽化工大學材料科學與工程學院 沈陽 110142

    1. 本站搜索
    2. 百度學術搜索
    3. 萬方數據庫搜索
    4. CNKI搜索
    Article views (187) PDF downloads(17) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return
    久色视频