Volume 31 Issue 6
Aug.  2021
Turn off MathJax
Article Contents
DENG Xin-sui, ZHANG Yang, ZHANG Ju-bing, LIU Jun-jin, MOU Zai-gen. Aseismic performance of a full-scale model of a two-storied frame structure with dense grid of slender columns[J]. Chinese Journal of Engineering, 2009, 31(6): 674-678. doi: 10.13374/j.issn1001-053x.2009.06.020
Citation: DENG Xin-sui, ZHANG Yang, ZHANG Ju-bing, LIU Jun-jin, MOU Zai-gen. Aseismic performance of a full-scale model of a two-storied frame structure with dense grid of slender columns[J]. Chinese Journal of Engineering, 2009, 31(6): 674-678. doi: 10.13374/j.issn1001-053x.2009.06.020

Aseismic performance of a full-scale model of a two-storied frame structure with dense grid of slender columns

doi: 10.13374/j.issn1001-053x.2009.06.020
  • Received Date: 2008-07-10
    Available Online: 2021-08-09
  • In order to investigate the aseismie performance of a kind of newly developed frame structure with dense grid of slender concrete columns in walls, a quasi-static test under reciprocating lateral loads was conducted for a full-scale two-storied modal frame and the experimental results were introduced. As a comparative study, the static elastoplastic push-over analyses were performed using different softwares of ABAQUS, SAP2000 and PKPM. Compared with the experimental results, the analyzed FEM models exhibited the same crack propagation patterns in walls, and the plastic hinge points also coincided with the experimental results. Finally, a capacity spectrum was obtained to evaluate the aseismic performance of the experimental model; its aseismic performance under eight-degree rare earthquake was evaluated. It is concluded that the aseismic performance of the frame structure with dense grid of concrete columns is considerably good.

     