Volume 16 Issue S1
Nov.  2021
Turn off MathJax
Article Contents
Li Jiuqing, Sun Dongbo, Wu Yinshun, Fang Zhi, Cui Zaiming, Jiang Guang. Determing the Susceptibility of 304L Austenitic Stainless Steel to Intergranular Corrosion by Square-wave Potentiostatic Pulse Technique[J]. Chinese Journal of Engineering, 1994, 16(S1): 52-58. doi: 10.13374/j.issn1001-053x.1994.s1.011
Citation: Li Jiuqing, Sun Dongbo, Wu Yinshun, Fang Zhi, Cui Zaiming, Jiang Guang. Determing the Susceptibility of 304L Austenitic Stainless Steel to Intergranular Corrosion by Square-wave Potentiostatic Pulse Technique[J]. Chinese Journal of Engineering, 1994, 16(S1): 52-58. doi: 10.13374/j.issn1001-053x.1994.s1.011

Determing the Susceptibility of 304L Austenitic Stainless Steel to Intergranular Corrosion by Square-wave Potentiostatic Pulse Technique

doi: 10.13374/j.issn1001-053x.1994.s1.011
  • Received Date: 1993-09-16
    Available Online: 2021-11-13
  • The susceptibility of AISI 304L austenitic stainless steel to intergranular attack mainly caused by the Cr-depletion in grain boundaries was detected by the square-wave potentiostatic pulse technique. The degree of the sensitization of 304L stainless steel can be exactly and quantitively illustrated by this technique.The maximum reactivation current density corresponding to 10th pulse,ir10,was selected as a characteristic parameter for the detection of sensitization.The degree of the sensitization determined by square-wave potentiostatic pulse technique was in agreement with those obtained from DL-EPR and ASTM standard tests.

     