<listing id="l9bhj"><var id="l9bhj"></var></listing>
<var id="l9bhj"><strike id="l9bhj"></strike></var>
<menuitem id="l9bhj"></menuitem>
<cite id="l9bhj"><strike id="l9bhj"></strike></cite>
<cite id="l9bhj"><strike id="l9bhj"></strike></cite>
<var id="l9bhj"></var><cite id="l9bhj"><video id="l9bhj"></video></cite>
<menuitem id="l9bhj"></menuitem>
<cite id="l9bhj"><strike id="l9bhj"><listing id="l9bhj"></listing></strike></cite><cite id="l9bhj"><span id="l9bhj"><menuitem id="l9bhj"></menuitem></span></cite>
<var id="l9bhj"></var>
<var id="l9bhj"></var>
<var id="l9bhj"></var>
<var id="l9bhj"><strike id="l9bhj"></strike></var>
<ins id="l9bhj"><span id="l9bhj"></span></ins>
Volume 6 Issue 2
Nov.  2021
Turn off MathJax
Article Contents
Ye Xingpu, Liu Xilin, Zhu Yuankai. The Direct Measurement Method of Conductivity Different Depth Method[J]. Chinese Journal of Engineering, 1984, 6(2): 105-111. doi: 10.13374/j.issn1001-053x.1984.02.009
Citation: Ye Xingpu, Liu Xilin, Zhu Yuankai. The Direct Measurement Method of Conductivity Different Depth Method[J]. Chinese Journal of Engineering, 1984, 6(2): 105-111. doi: 10.13374/j.issn1001-053x.1984.02.009

The Direct Measurement Method of Conductivity Different Depth Method

doi: 10.13374/j.issn1001-053x.1984.02.009
  • Available Online: 2021-11-08
  • By taking the exact size of the conductivity cell as well as the resistance values at diffevent depth, the conductivity was calculated using the following equation:\[\begin{array}{l}\sigma = \frac{1}{{2\pi \Delta {\rm{h}}}}{\rm{(}}\frac{{\rm{1}}}{{{{\rm{R}}_{\rm{2}}}}}{\rm{ - }}\frac{{\rm{1}}}{{{{\rm{R}}_{\rm{1}}}}}{\rm{)ln(}}\frac{{{{\rm{D}}_{\rm{2}}}{\rm{ - m}}}}{{{{\rm{D}}_{\rm{1}}}{\rm{ - m}}}}{\rm{ \bullet }}\frac{{{{\rm{r}}_{\rm{1}}}}}{{{{\rm{r}}_{\rm{2}}}}}{\rm{)}}\\{\rm{or}}\\\sigma = \frac{{{{\rm{K}}^*}}}{{\Delta {\rm{h}}}}{\rm{(}}\frac{{\rm{1}}}{{{{\rm{R}}_{\rm{2}}}}}{\rm{ - }}\frac{{\rm{1}}}{{{{\rm{R}}_{\rm{1}}}}}{\rm{)}}\end{array}\]Therefore, the procedure of demarcating the constant of the conductivity cell by using a know solution can be omitted.With this new mefhod, the experimental procedure has been simplified and the results proved accurate.

     

  • loading
  • 加載中

Catalog

    通訊作者: 陳斌, bchen63@163.com
    • 1. 

      沈陽化工大學材料科學與工程學院 沈陽 110142

    1. 本站搜索
    2. 百度學術搜索
    3. 萬方數據庫搜索
    4. CNKI搜索
    Article views (229) PDF downloads(10) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return
    久色视频