<listing id="l9bhj"><var id="l9bhj"></var></listing>
<var id="l9bhj"><strike id="l9bhj"></strike></var>
<menuitem id="l9bhj"></menuitem>
<cite id="l9bhj"><strike id="l9bhj"></strike></cite>
<cite id="l9bhj"><strike id="l9bhj"></strike></cite>
<var id="l9bhj"></var><cite id="l9bhj"><video id="l9bhj"></video></cite>
<menuitem id="l9bhj"></menuitem>
<cite id="l9bhj"><strike id="l9bhj"><listing id="l9bhj"></listing></strike></cite><cite id="l9bhj"><span id="l9bhj"><menuitem id="l9bhj"></menuitem></span></cite>
<var id="l9bhj"></var>
<var id="l9bhj"></var>
<var id="l9bhj"></var>
<var id="l9bhj"><strike id="l9bhj"></strike></var>
<ins id="l9bhj"><span id="l9bhj"></span></ins>
Volume 42 Issue 5
May  2020
Turn off MathJax
Article Contents
YAO Xi-tong, DAI Yu, ZHANG Jian-xun, GE Jin-tao, CHEN Tong, YANG Hao. ECG filtering and QRS extraction under steep pulse interference[J]. Chinese Journal of Engineering, 2020, 42(5): 654-662. doi: 10.13374/j.issn2095-9389.2019.06.20.004
Citation: YAO Xi-tong, DAI Yu, ZHANG Jian-xun, GE Jin-tao, CHEN Tong, YANG Hao. ECG filtering and QRS extraction under steep pulse interference[J]. Chinese Journal of Engineering, 2020, 42(5): 654-662. doi: 10.13374/j.issn2095-9389.2019.06.20.004

ECG filtering and QRS extraction under steep pulse interference

doi: 10.13374/j.issn2095-9389.2019.06.20.004
More Information
  • Corresponding author: E-mail: daiyu@nankai.edu.cn
  • Received Date: 2019-06-20
  • Publish Date: 2020-05-01
  • Applying a steep pulse voltage of appropriate amplitude to a cell membrane can induce transient and reversible breakdown of the membrane, which has broad application prospects in biomedicine and clinical fields. However, the noise generated by the steep pulse seriously interferes with a patient’s electrocardiogram (ECG) signal resulting in decrease in the accuracy of the ECG feature point detection algorithm. Thus, doctors are unable to understand the state of the patient during treatment, thus limiting complete benefits of the therapy. To eliminate the interference caused by the steep pulse, we analyzed the characteristics of steep pulse interference and established the mathematical model of steep pulse noise. Moreover, we proposed an ECG signal filtering algorithm based on variational mode decomposition (VMD) to extract the steep pulse interference component superimposed on the ECG signal. The proposed algorithm could identify and eliminate the steep pulse interference component. We also designed an ECG signal preprocessing algorithm to reduce the decomposition layer of the VMD algorithm, which improved the real-time performance and reduced the memory consumption. To identify the random noise in the medical environment accompanied by the occurrence of steep pulses, we analyzed the characteristics of random noise in the sub-signal after VMD. Further, we proposed a threshold denoising algorithm based on VMD for sub-signal energy estimation. On the basis of the characteristics of a band-pass filter bank with VMD, we proposed a QRS complex detection algorithm based on VMD sub-signal recombination. Combined with the filtering algorithm, the proposed algorithm was able to improve the accuracy of ECG signal detection. By conducting experiments on ECG signals from the MIT–BIH database with Gaussian white noise and simulated steep pulse interference and those collected in the medical environment, we compared and analyzed the filtering algorithm and QRS complex detection algorithm.

     

  • loading
  • [1]
    Prausnitz M R, Bose V G, Langer R, et al. Electroporation of mammalian skin: a mechanism to enhance transdermal drug delivery. Proc Natl Acad Sci USA, 1993, 90(22): 10504 doi: 10.1073/pnas.90.22.10504
    [2]
    呂東澔, 張建勛, 代煜. 陡脈沖發生器電路中雜散參數的分析和補償. 工程科學學報, 2016, 38(5):734

    Lü D H, Zhang J X, Dai Y. Analysis and compensation of stray parameters in high-voltage pulse generator circuits. Chin J Eng, 2016, 38(5): 734
    [3]
    Gehl J. Electroporation: theory and methods, perspectives for drug delivery, gene therapy and research. Acta Physiol Scand, 2003, 177(4): 437 doi: 10.1046/j.1365-201X.2003.01093.x
    [4]
    金聲瑯, 王瑩, 殷涌光. 高壓脈沖電場對淀粉和肌原纖維蛋白混合凝膠強度的影響. 吉林大學學報: 工學版, 2014, 44(2):573

    Jin S L, Wang Y, Yin Y G. Effect of high intensity pulsed electric field pretreatment on elasticity of starch-myofibril protein mixed gelatin. J Jilin Univ Eng Technol Ed, 2014, 44(2): 573
    [5]
    馮敘橋, 王月華, 徐方旭. 高壓脈沖電場技術在食品質量與安全中的應用進展. 食品與生物技術學報, 2013, 32(4):337 doi: 10.3969/j.issn.1673-1689.2013.04.001

    Feng X Q, Wang Y H, Xu F X. Advances on application of high voltage pulsed electric field in food quality and safety. J Food Sci Biotechnol, 2013, 32(4): 337 doi: 10.3969/j.issn.1673-1689.2013.04.001
    [6]
    Maor E, Ivorra A, Leor J, et al. The effect of irreversible electroporation on blood vessels. Technol Cancer Res Treat, 2007, 6(4): 307 doi: 10.1177/153303460700600407
    [7]
    Zhang R Y, Fang X, Liu Y Q, et al. Design of a real-time ECG filter for resource constraint computer // 2012 International Conference on Information and Automation (ICIA). Shenyang, 2012: 846
    [8]
    王磊, 孫瑋, 陳奕博, 等. 基于自適應小波閾值的心電信號降噪方法. 計算機工程與應用, 2018, 54(15):29 doi: 10.3778/j.issn.1002-8331.1805-0352

    Wang L, Sun W, Chen Y B, et al. ECG denoising method based on adaptive wavelet threshold selection. Comput Eng Appl, 2018, 54(15): 29 doi: 10.3778/j.issn.1002-8331.1805-0352
    [9]
    Tan X, Chen X X, Hu X Y, et al. EMD-based electrocardiogram delineation for a wearable low-power ECG monitoring device. Can J Electr Comput Eng, 2014, 37(4): 212 doi: 10.1109/CJECE.2014.2316852
    [10]
    Dragomiretskiy K, Zosso D. Variational mode decomposition. IEEE Trans Signal Process, 2014, 62(3): 531 doi: 10.1109/TSP.2013.2288675
    [11]
    陳穗, 郭蒙召, 張建勛. 高壓陡脈沖發生器的設計與實現. 自動化與儀表, 2019, 34(2):5 doi: 10.3969/j.issn.1001-9944.2019.02.002

    Chen S, Guo M Z, Zhang J X. Design and realization of high-voltage steep pulse generator. Autom Instrum, 2019, 34(2): 5 doi: 10.3969/j.issn.1001-9944.2019.02.002
    [12]
    Wang Y X, Markert R. Filter bank property of variational mode decomposition and its applications. Signal Process, 2016, 120: 509 doi: 10.1016/j.sigpro.2015.09.041
    [13]
    張東, 馮志鵬. 基于變分模式分解和微積分增強能量算子的滾動軸承故障診斷. 工程科學學報, 2016, 38(9):1327

    Zhang D, Feng Z P. Fault diagnosis of rolling bearings based on variational mode decomposition and calculus enhanced energy operator. Chin J Eng, 2016, 38(9): 1327
    [14]
    Xue Y J, Cao J X, Wang D X, et al. Application of the variational-mode decomposition for seismic time-frequency analysis. IEEE J Selected Topics Appl Earth Observ Remote Sens, 2016, 9(8): 3821 doi: 10.1109/JSTARS.2016.2529702
    [15]
    Liu Y Y, Yang G L, Li M, et al. Variational mode decomposition denoising combined the detrended fluctuation analysis. Signal Process, 2016, 125: 349 doi: 10.1016/j.sigpro.2016.02.011
    [16]
    曹細武, 鄧親愷. 心電圖各波的頻率分析. 中國醫學物理學雜志, 2001, 18(1):46 doi: 10.3969/j.issn.1005-202X.2001.01.021

    Cao X W, Deng Q K. Frequency analysis on the ECG waveform. Chin J Med Phys, 2001, 18(1): 46 doi: 10.3969/j.issn.1005-202X.2001.01.021
    [17]
    魯亞磊, 王瑞, 胡敏露, 等. 穿戴式心電及心振信號監測系統的研制. 北京生物醫學工程, 2018, 37(4):381 doi: 10.3969/j.issn.1002-3208.2018.04.009.

    Lu Y L, Wang R, Hu M L, et al. Development of wearable ECG and SCG monitoring system. Beijing Biomed Eng, 2018, 37(4): 381 doi: 10.3969/j.issn.1002-3208.2018.04.009.
    [18]
    Kopsinis Y, McLaughlin S. Development of EMD-based denoising methods inspired by wavelet thresholding. IEEE Trans signal Process, 2009, 57(4): 1351 doi: 10.1109/TSP.2009.2013885
    [19]
    Hamilton P S, Tompkins W J. Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database. IEEE Trans Biomed Eng, 1986, 33(12): 1157
    [20]
    劉增丁, 陳驥, 湯敏芳. 基于波形時域特征和動態差分閾值的脈搏波傳導時間檢測算法. 生物醫學工程學雜志, 2017, 34(3):329

    Liu Z D, Chen J, Tang M F. Pulse transit time detection based on waveform time domain feature and dynamic difference threshold. J Biomed Eng, 2017, 34(3): 329
    [21]
    Pan J P, Tompkins W J. A real-time QRS detection algorithm. IEEE Trans Biomed Eng, 1985, 32(3): 230
  • 加載中

Catalog

    通訊作者: 陳斌, bchen63@163.com
    • 1. 

      沈陽化工大學材料科學與工程學院 沈陽 110142

    1. 本站搜索
    2. 百度學術搜索
    3. 萬方數據庫搜索
    4. CNKI搜索

    Figures(13)  / Tables(3)

    Article views (2028) PDF downloads(55) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return
    久色视频