Zhang Xingkai. Fume Temperature Below Fire Area in Roadway[J]. Chinese Journal of Engineering, 1995, 17(1): 19-22. doi: 10.13374/j.issn1001-053x.1995.01.005
Citation: Zhang Xingkai. Fume Temperature Below Fire Area in Roadway[J]. Chinese Journal of Engineering, 1995, 17(1): 19-22. doi: 10.13374/j.issn1001-053x.1995.01.005

Fume Temperature Below Fire Area in Roadway

doi: 10.13374/j.issn1001-053x.1995.01.005
  • Received Date: 1994-05-10
    Available Online: 2021-09-06
  • A fire test is designed in a experimental roadway during 218min, which is 5.4m2 in section and 70m in long, the fire process and the temperature of below the fire area are studied. There are three stages in the case of without no extinguishing:oping stage, stable stage and failing stage.

     