Kelvin probe study on initial corrosion of carbon steel and weathering steel under atmosphere with Cl-
-
摘要: 利用掃描Kelvin探針(SKP)技術,結合腐蝕產物的形貌分析和物相分析,研究了Q235碳鋼和Q450耐候鋼在鹽霧腐蝕實驗早期階段的腐蝕行為和電位分布.結果表明,Cl-對碳鋼有強烈的侵蝕作用,在鹽霧腐蝕過程的初期,金屬表面出現明顯的陰極區和陽極區,表面電位隨時間逐步正移,呈現局部腐蝕的特征,且由于合金元素的作用,Q450耐候鋼腐蝕較為均勻,SKP測試的表面電位高于Q235碳鋼,形成的銹層較為致密,耐大氣腐蝕性能優于Q235碳鋼.
-
關鍵詞:
- 碳鋼 /
- 耐候鋼 /
- 大氣腐蝕 /
- 氯離子 /
- 掃描KELVIN探針
Abstract: The scanning Kelvin probe (SKP) technique, in combination with energy dispersive spectrum (EDS) analysis of corrosion products, was employed to investigate the initial corrosion behavior and potential distribution of Q235 carbon steel and Q450 weathering steel during salt spray test. The results showed that Q235 carbon steel was severely attacked by Cl-. During the initial period of salt spray test, anodic and cathodic areas formed on the surface of the specimens and the surface potential became more and more positive in the corrosion procedure with a distinct character of localized corrosion. The SKP results showed that Q450 weathering steel was inclined to uniform corrosion, whose surface potential was more positive than that of Q235 carbon steel, probably being due to the effect of alloying elements. The product layer of Q450 was more compact, which indicated that Q450 was more resistive to atmospheric corrosion than Q235.-
Key words:
- carbon steel /
- weathering steel /
- atmospheric corrosion /
- chlorine ions /
- scanning Kelvin probe
-