Shaking table test of pier-water intereaction
-
摘要: 以南京長江三橋南塔墩作為工程背景,并按照1:50的相似比設計出橋墩的模型,并選取正弦波和天津波作為加載的波形,在無水與有水兩種狀態下開展了振動臺試驗.試驗數據表明,承臺部分的加速度視加載波形峰值的不同有20%到40%的增幅,位移、應變等也有相應的增幅.通過試驗得出的動水壓力沿高程分布圖表明,動水壓力的分布與地震波強度明顯相關.Abstract: Taking the Third Nanjing Yangtze River Bridge as an engineering background,a pile-cap pier model was designed and built by using the similar principles with a scale factor of 1∶50.A shaking table test of this pier model was carried out by loading a sine wave and Tianjin wave in the two cases around water and around air.The result showed that the largest rate of acceleration increased from 20% to 40% under different waves,and the displacement and strain increased accordingly.The curves of earthquake hydrodynamic pressure along pile height indicated that the distribution of pressure was relevant to the intensity of earthquake waves.
-
Key words:
- piers /
- fluid structure interaction /
- earthquake /
- shaking table test
-

計量
- 文章訪問數: 101
- HTML全文瀏覽量: 17
- PDF下載量: 8
- 被引次數: 0