Determination of a and E0 on Cathodic Protection System of Underground Pipelines with Sacrificial Anodes
-
摘要: 通過對埋地煤氣管線實施犧牲陽極陰極保護的大量測試數據,經系統整理分析,得出電位衰減系數a與修正系數r和涂層電導之間的關系,以及通電點管地電位偏移量E0的計算公式。Abstract: The equation of negative shift “E0” of pipe/ground potential at connection point, the relation-ship between potential attenuation coefficient “a” and calibration coefficient “r” as well as electric conductivity “g1” of coating are dedueecl by systematic analysis a vast amount of experimental data collected from cathodic protection system of underground pipelines with sacrificial anodes.
-
Key words:
- pipe/groud potential /
- attenuation coefficient /
- cathodic protection
-

計量
- 文章訪問數: 174
- HTML全文瀏覽量: 69
- PDF下載量: 37